站内搜索
|
详细信息 Product Name: Agsno2 Contact Material Relay for Intelligent Control Model NO.: W39 Type: Electric Parameter Relay Size: Miniature Action Principle: Electromagnetic Type Protective Characteristics: Sealed Relay Load: Micro Power Relay Electricity Type: Dc Usage: Household Appliances Relay, Communication Relay, Lathe Relay Theory: Electromagnetic Relay Certification: UL TUV CQC Contact Material: Agsno2 Installation Type: PCB UL Insulation Class: F Operate Time: Max.15ms Release Time: Max.5ms Weight: 15g Trademark: Fanhar Transport Package: Export Carton Specification: 29*12.7*25(mm) Origin: China HS Code: 8536411000 Product Description Basic InfoModel NO.:W39Contact Form:1A= 1OPEN 1C = 1 Transformation PCB Mounting: 1 = type 1 2= type 2Product protective: S=Sealed Nil= Soldered Contact material: T = AgSnO2 Coil Power: Nil = 530mW L= 360mW Insulation level: B: B level F: F level Dimension:29*12.7*25 MMWeight: Approx 15gTrademark:FANHAROrigin:ChinaProduct Description1. 16A contact switching capability 2.Normally open type has the UL certification of TV-8 125VAC, the impact current is 120A3.The withstand voltage between coil and contact can reach 10KV4. Optional socket installationContact data:Contact Form1A 1C Rated load 16A 250VAC/30VDC 12A 250VAC/30VDC Max Switching Voltage277VAC/ 30VDC Max Switching Current16A Max SwitchingCapacity 4000VA/480WMin Allowing load 5VDC 100mA Contact Resistance100mΩ(at 6VDC 1A)Insulation Resistance 1000MΩ (at 500VDC)General data:Withstand Voltage Between open contacts1000VAC 1min Between coil and contacts 4000VAC 1minOperate TimeMax.15msRelease TimeMax.5msMechanical life 10,000,000 ops ON/OFF = 0.1s/0.1sElectrical life 16A 250VAC /30VDC 100,000 ops ON/OFF=1s/9s12A 250VAC /30VDC 100,000 ops ON/OFF=1s/9sImpact Resistance Misoperation Durability 100m/s² Approx10G1000m/s² Approx100GVibration Resistance Misoperation Durability 10 - 55Hz 1.5mm Double Amplitude 10 - 55Hz 1.5mm Double AmplitudeTemperature Range-40ºCto +70ºCHumidity5% to 90% Installation type PCB Mounting CertificationUL TUV ISO CQCCoil data:Standard:Coil rated voltageOperating voltageReleasing Voltage Coil rated Current(±10%)Coil resistance(±10%)Rated consumed powerAllowing voltage DC 5VBelow 75% rated voltage (initial)above 5%rated voltage (initial) 106mA47Ω530mW90-130 %Rated voltageDC 6V58.8mA153ΩDC 12V44.2mA272ΩDC 24V22.1mA1087ΩDC 48V11.5mA4170ΩDC 100V5.3mA18860ΩSensitive:Coil rated voltageOperating voltageReleasing Voltage Coil rated Current(±10%)Coil resistance(±10%)Rated consumed powerAllowing voltage DC 5VBelow 75% rated voltage (initial)above 5%rated voltage (initial) 71.4mA70Ω360mW90-130 %Rated voltageDC 6V60mA100ΩDC 12V30mA400ΩDC 24V15mA1600ΩDC 48V7.5mA6400Ω
|